RLC-4 Command Number Translation V1.30 command numbers on the left, new equivalent command numbers on the right. N/A indicates that no equivalent command exists. Sorted by old command number. old command # new command # Description Comments 0 0 cmd_connect_ports 1 1 cmd_monitor_port 2 2 cmd_disconnect_ports 3 3 cmd_recall_connections_to_rx 4 4 cmd_recall_connections_to_tx 5 5 cmd_set_access_mode 6 6 cmd_recall_access_mode 7 7 cmd_set_dtmf_mute 8 7 recall dtmf mute - use command 7 9 9 cmd_recall_xpt 10 10 cmd_change_command_name 11 11 cmd_recall_command_name 12 12 cmd_recall_command_number 13 13 cmd_set_cor_pl_polarity 14 14 not used 15 15 not used 16 16 not used 17 17 not used 18 18 not used 19 19 not used 20 20 cmd_set_timer_length 21 21 cmd_recall_timer_length 22 22 cmd_start_timer 23 23 cmd_stop_timer 24 n/a not used 25 26 play dvr 26 25 record dvr 27 27 erase dvr 28 28 not used 29 29 not used 30 30 send cw 31 42 set cw speed 32 43 set cw tone frequency 33 31 send dtmf sequence 34 44 set up dtmf regenerate parameters 35 32 send serial 36 24 set baud rate 37 35 remote reset 38 n/a not used 39 n/a not used 40 40 send tone 41 n/a 42 37 set audio routing 43 38 clear audio routing 44 39 recall audio routing 45 50 set/recall routing defaults 46 50 set/recall routing defaults 47 51 start preaccess tone 48 49 set preaccess tone freq Must specify 9 digits, should only require 5 49 n/a not used 50 53 program macro 51 54 recall macro 52 55 delete macro 53 56 append macro 54 57 copy macro 55 58 delete cmd in macro 56 59 insert cmd in macro 57 45 set event trigger 58 46 recall event trigger should combine with 45 59 47 enable/disable event trigger should combine with 45 60 60 set serial options 61 61 disconnect all 62 62 change start of cmd names 63 63 not used 64 64 not used 65 n/a not used 66 66 not used 67 67 not used 68 68 not used 69 69 not used 70 73 set/recall preaccess 71 73 set/recall preaccess 72 73 set/recall preaccess 73 73 set/recall preaccess 74 74 port preaccessed 75 75 set stop access conditions 76 76 recall stop access conditions should combine with 75 77 77 isolate port 78 78 set cmd executor options 79 79 recall cmd executor options should combine with 78 80 n/a autoexecution - no longer needed - use timed execution (command 078) 81 n/a no longer needed 82 n/a no longer needed 83 149 do nothing 84 84 not used 85 85 IDs on/off 86 86 recall IDs on/off should combine with 085 87 87 not used 88 88 not used 89 89 not used 90 90 read inputs 91 91 execute input line macro 92 n/a turn input line alarms on/off - use 047 instead 93 93 turn output(s) on should combine 93..95 like doug hall output command 94 94 turn output(s) off 95 95 recall output state 96 96 not used 97 97 not used 98 98 not used 99 99 not used on RLC-4, turns output on/off on RLC-5 100 100 cmd_read_analog_line 101 101 cmd_set_analog_precision 102 102 cmd_set_analog_conversion 103 103 cmd_calibrate_analog 104 104 cmd_set_analog_alarm 105 105 cmd_set_analog_alarm_hysteresis 106 n/a enable/disable analog alarm - use 047 instead 107 107 recall analog lines in alarm 108 108 recall analog configuration 109 117 forward dial, no long distance checks, no predial digits 110 110 set up patch 111 111 manual off hook 112 112 normal forward dial 113 113 forward dial, no long distance checks 114 114 hang up 115 116 set/recall predial digits 116 116 set/recall predial digits 117 119 set allowed number 118 120 recall allowed number should combine with 119 119 121 set nuisance number - "antidialer" 120 122 recall nuisance should combine with 121 121 128 set half duplex patch mode 122 129 recall half duplex patch mode should combine with 128 123 133 set up reverse patch 124 134 reverse patch log on 125 135 answer reverse patch 126 136 set up reverse patch ring 127 130 block execution from a port 128 131 allow execution from a port should combine with 130 129 132 recall execution mask should combine with 130 130 140 Set Band Unit , Power Level and Offset Defaults for RBI-1 131 142 Set Frequency (and optionally offset) for RBI-1 132 141 Set PL Frequency for RBI-1, Encode and Decode Settings 133 143 Frequency and Offset Recall for the RBI-1 134 n/a Error Message 00 - now sent by command 048 135 n/a Error Message 01 - now sent by command 048 136 n/a Error Message 02 - now sent by command 048 137 n/a Error Message 03 - now sent by command 048 138 n/a Error Message 04 - now sent by command 048 139 n/a Error Message 05 - now sent by command 048 140 n/a Error Message 06 - now sent by command 048 141 n/a Error Message 07 - now sent by command 048 142 n/a Error Message 08 - now sent by command 048 143 n/a Error Message 09 - now sent by command 048 144 n/a Error Message 10 - now sent by command 048 145 n/a Error Message 11 - now sent by command 048 146 n/a Error Message 12 - now sent by command 048 147 n/a Error Message 13 - now sent by command 048 148 148 not used 149 n/a not used n/a 8 cmd_recall_software_version n/a 33 supervisory ptt on/off - like rlc3 155 n/a 34 recall supervisory ptt should combine with 33 n/a 36 not used n/a 41 turn courtesy beep on/off n/a 52 not used n/a 65 restore audio routing (undo 37 and 38) n/a 80 execute command by number "Nxxx" n/a 81 not used n/a 82 not used n/a 83 not used n/a 92 unused n/a 106 not used n/a 109 not used n/a 115 possibly hang up n/a 118 not used n/a 123 not used n/a 124 not used n/a 125 not used n/a 126 not used n/a 127 not used n/a 137 not used n/a 138 not used n/a 139 set up RLC-ICM n/a 144 Turn Doug Hall RBI-1 Output On/Off n/a 145 not used n/a 146 not used n/a 147 not used