RLC-1 VERSION 2.06 Fixes a crosspoint bug. RLC-1 VERSION 2.05 1) ADDED A DROP-OUT MESSAGE COUNTER. THE COUNTER CAN BE SET FROM 01 TO 99. WHEN THE COUNTER IS SET TO 01 THE DROP-OUT MESSAGE WILL BE SENT EVERY TIME. WHEN THE COUNTER IS SET TO 02 THEN THE DROP-OUT MESSAGE WILL BE SENT EVERY OTHER TIME, AN SO ON... COMMAND 069 PROGRAMS, AND RECALLS THE DROP-OUT TIMER COUNTER TO PROGRAM THE COUNTER <069> P TT WHERE P IS THE PORT NUMBER: 1 OR 2 CC IS THE COUNTER NUMBER FROM 01..99 TO RECALL THE COUNTER <069> P WHERE P IS THE PORT NUMBER: 1 OR 2 ERRORS ASSOCIATED WITH THIS COMMAND ERROR 1: INVALID AMOUNT OF DATA. MUST BE EITHER 1 OR 3 DIGITS AFTER THE COMMAND NAME ERROR 2: INVALID PORT NUMBER. MUST BE EITHER PORT 1 OR PORT 2 ERROR 3: INVALID DATA COUNTER. MUST BE BETWEEN 01 AND 99 ** NOTE ** YOU CAN STILL DISABLE THE EVENT LIKE NORMAL USING COMMAND 065 (EVENT TABLE). THIS COMMAND ONLY ALLOWS YOU TO CONTROL HOW MANY TIMES THE DROP-OUT TIMER IS SENT. DEFINITION: DROP-OUT EVENTS ARE ONLY SENT AFTER THE HANG TIMER RUNS OUT. THIS COMMAND DOES NOT CHANGE THAT. THE DROP-OUT COUNTER IS DECREMENTED EACH TIME A DROP-OUT EVENT IS REQUESTED. IF THE DROP-OUT COUNTER IS NOT ZERO, THE DROP-OUT EVENT IS SKIPPED. 2) FIXED THE CALIBRATION ON THE ANALOG TEMPERATURE SENSORS (FACEPLATE 06,07). CONTACT: Link Communications, Inc. 1035 Cerise Rd Billings, MT 59101-7378 VOICE: 406-245-5002 FAX: 406-245-4889